Cheapest Factory aspergillus galactomannan rapid test - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of Serum Amyloid A, SARS-CoV-2 nuclear acid, fungus testing kit, If you have the requirement for virtually any of our items, make sure you call us now. We are wanting ahead to hearing from you before long.
Cheapest Factory aspergillus galactomannan rapid test - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

FungiXpert® Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) uses colloidal gold immunochromatography technology to detect aspergillus-specific IgG antibody in human serum, providing a rapid and effective auxiliary aid for the diagnosis of susceptible populations.

Invasive fungal diseases (IFD) have become one of the biggest life threats to immunocompromised patients and have caused high morality worldwide. Aspergillus species are ubiquitous, saprophytic fungi that are important causes of morbidity and mortality in transplant recipients. Humans become infected with Aspergillus after conidia are inhaled and deposited in bronchioles, in alveolar spaces, and less commonly in paranasal sinuses. Most common Aspergillus pathogens include Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, Aspergillus terreus.

Chronic pulmonary aspergillosis (CPA) is an underdiagnosed and misdiagnosed disease and now increasingly recognised. However, the diagnosis of CPA remains challenging. Recent studies have found the diagnostic values of serum Aspergillus-specific IgG and IgM antibodies in patients with CPA. The Infectious Diseases Society of America (IDSA) have recommended that Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA).

Characteristics

Name

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Serum

Specification

25 tests/kit; 50 tests/kit

Detection time

10 min

Detection objects

Aspergillus spp.

Stability

The K-Set is stable for 2 years at 2-30°C

Low detection limit

5 AU/mL

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Advantage

  • Simple and accurate
    Easy to use, ordinary laboratory staff can operate without training
    Intuitive and visual reading result
  • Accurate and economical
    Low detection limit: 5 AU/mL
    Transported and stored at room temperature, reducing costs
  • Rapid and convenient
    Obtain result within 10 min
    Two specifications available: cassette/25T; strip/50T
  • Support the diagnosis of aspergillosis in early stage
    Aspergillus-specific IgG antibodies take a mean of 10.8 days to appear in acute illness
  • Detection of single immunoglobulin subtype demonstrate the infection stage
    Relationship between antibody concentration and Aspergillus infection

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 1

  • Recommended by ESCMID/ECMM/ERS/IDSA etc
    IgG antibody response to Aspergillus spp. is one of the characteristics required for the diagnosis of CPA.
    Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA)
    Antibody diagnosis of chronic pulmonary aspergillosis (CPA)
Population Intention Intervention SoR QoE
Cavitary or nodular pulmonary infiltrate in
non-immunocompromised patients
Diagnosis or exclusion of CPA Aspergillus IgG antibody A II
  • Applicable department

Respiration department
Cancer department
Hematology department

ICU
Transplantation department
Infectious department

Operation

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 3
Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

AGLFA-01

25 tests/kit, cassette format

FGM025-002

AGLFA-02

50 tests/kit, strip format

FGM050-002


Product detail pictures:

Cheapest Factory aspergillus galactomannan rapid test - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

The corporation upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will proceed to provide aged and new buyers from home and abroad whole-heatedly for Cheapest Factory aspergillus galactomannan rapid test - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: moldova, Denver, Grenada, Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our solutions, you should do not hesitate to contact us for further information.
  • It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Andrew from Ecuador - 2017.11.11 11:41
    As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Judith from Sierra Leone - 2017.06.16 18:23
    Write your message here and send it to us