China New Product Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

We stick with the theory of "quality first, company first, steady improvement and innovation to satisfy the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our provider, we deliver the items together with the fantastic good quality at the reasonable value for bacterial test, corona virus test, cryptococcus EIA, We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.
China New Product Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

FungiXpert® Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) uses colloidal gold immunochromatography technology to detect aspergillus-specific IgG antibody in human serum, providing a rapid and effective auxiliary aid for the diagnosis of susceptible populations.

Invasive fungal diseases (IFD) have become one of the biggest life threats to immunocompromised patients and have caused high morality worldwide. Aspergillus species are ubiquitous, saprophytic fungi that are important causes of morbidity and mortality in transplant recipients. Humans become infected with Aspergillus after conidia are inhaled and deposited in bronchioles, in alveolar spaces, and less commonly in paranasal sinuses. Most common Aspergillus pathogens include Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, Aspergillus terreus.

Chronic pulmonary aspergillosis (CPA) is an underdiagnosed and misdiagnosed disease and now increasingly recognised. However, the diagnosis of CPA remains challenging. Recent studies have found the diagnostic values of serum Aspergillus-specific IgG and IgM antibodies in patients with CPA. The Infectious Diseases Society of America (IDSA) have recommended that Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA).

Characteristics

Name

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Serum

Specification

25 tests/kit; 50 tests/kit

Detection time

10 min

Detection objects

Aspergillus spp.

Stability

The K-Set is stable for 2 years at 2-30°C

Low detection limit

5 AU/mL

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Advantage

  • Simple and accurate
    Easy to use, ordinary laboratory staff can operate without training
    Intuitive and visual reading result
  • Accurate and economical
    Low detection limit: 5 AU/mL
    Transported and stored at room temperature, reducing costs
  • Rapid and convenient
    Obtain result within 10 min
    Two specifications available: cassette/25T; strip/50T
  • Support the diagnosis of aspergillosis in early stage
    Aspergillus-specific IgG antibodies take a mean of 10.8 days to appear in acute illness
  • Detection of single immunoglobulin subtype demonstrate the infection stage
    Relationship between antibody concentration and Aspergillus infection

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 1

  • Recommended by ESCMID/ECMM/ERS/IDSA etc
    IgG antibody response to Aspergillus spp. is one of the characteristics required for the diagnosis of CPA.
    Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA)
    Antibody diagnosis of chronic pulmonary aspergillosis (CPA)
Population Intention Intervention SoR QoE
Cavitary or nodular pulmonary infiltrate in
non-immunocompromised patients
Diagnosis or exclusion of CPA Aspergillus IgG antibody A II
  • Applicable department

Respiration department
Cancer department
Hematology department

ICU
Transplantation department
Infectious department

Operation

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 3
Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

AGLFA-01

25 tests/kit, cassette format

FGM025-002

AGLFA-02

50 tests/kit, strip format

FGM050-002


Product detail pictures:

China New Product Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

We are ready to share our knowledge of marketing worldwide and recommend you suitable products at most aggressive costs. So Profi Tools offer you finest benefit of money and we are ready to produce alongside one another with China New Product Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Malta, United Arab Emirates, Malta, Strict quality control is executed in each link of the whole production process.We sincerely hope to establish the friendly and mutual-beneficial cooperation with you. Based on high quality products and perfect pre-sales /after-sales service is our idea, some clients had cooperated with us for more than 5 years.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Pearl Permewan from Bangladesh - 2018.11.11 19:52
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Miranda from Chile - 2018.02.08 16:45
    Write your message here and send it to us