Factory made hot-sale COVID-19 neutralizing antibody - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

It adheres on the tenet "Honest, industrious, enterprising, innovative" to develop new items frequently. It regards buyers, success as its very own success. Let us produce prosperous future hand in hand for CLIA analyzer, SARS-CoV-2 home use, Klebsiella pneumoniaecarbapenemase, Our experienced specialized group will be wholeheartedly at your support. We sincerely welcome you to check out our site and enterprise and send out us your inquiry.
Factory made hot-sale COVID-19 neutralizing antibody - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

FungiXpert® Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) uses colloidal gold immunochromatography technology to detect aspergillus-specific IgG antibody in human serum, providing a rapid and effective auxiliary aid for the diagnosis of susceptible populations.

Invasive fungal diseases (IFD) have become one of the biggest life threats to immunocompromised patients and have caused high morality worldwide. Aspergillus species are ubiquitous, saprophytic fungi that are important causes of morbidity and mortality in transplant recipients. Humans become infected with Aspergillus after conidia are inhaled and deposited in bronchioles, in alveolar spaces, and less commonly in paranasal sinuses. Most common Aspergillus pathogens include Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, Aspergillus terreus.

Chronic pulmonary aspergillosis (CPA) is an underdiagnosed and misdiagnosed disease and now increasingly recognised. However, the diagnosis of CPA remains challenging. Recent studies have found the diagnostic values of serum Aspergillus-specific IgG and IgM antibodies in patients with CPA. The Infectious Diseases Society of America (IDSA) have recommended that Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA).

Characteristics

Name

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Serum

Specification

25 tests/kit; 50 tests/kit

Detection time

10 min

Detection objects

Aspergillus spp.

Stability

The K-Set is stable for 2 years at 2-30°C

Low detection limit

5 AU/mL

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Advantage

  • Simple and accurate
    Easy to use, ordinary laboratory staff can operate without training
    Intuitive and visual reading result
  • Accurate and economical
    Low detection limit: 5 AU/mL
    Transported and stored at room temperature, reducing costs
  • Rapid and convenient
    Obtain result within 10 min
    Two specifications available: cassette/25T; strip/50T
  • Support the diagnosis of aspergillosis in early stage
    Aspergillus-specific IgG antibodies take a mean of 10.8 days to appear in acute illness
  • Detection of single immunoglobulin subtype demonstrate the infection stage
    Relationship between antibody concentration and Aspergillus infection

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 1

  • Recommended by ESCMID/ECMM/ERS/IDSA etc
    IgG antibody response to Aspergillus spp. is one of the characteristics required for the diagnosis of CPA.
    Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA)
    Antibody diagnosis of chronic pulmonary aspergillosis (CPA)
Population Intention Intervention SoR QoE
Cavitary or nodular pulmonary infiltrate in
non-immunocompromised patients
Diagnosis or exclusion of CPA Aspergillus IgG antibody A II
  • Applicable department

Respiration department
Cancer department
Hematology department

ICU
Transplantation department
Infectious department

Operation

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 3
Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

AGLFA-01

25 tests/kit, cassette format

FGM025-002

AGLFA-02

50 tests/kit, strip format

FGM050-002


Product detail pictures:

Factory made hot-sale COVID-19 neutralizing antibody - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

Good quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is regularly observed and pursued by our company for Factory made hot-sale COVID-19 neutralizing antibody - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Jordan, Sri Lanka, Portugal, Our company is continuing to serve customers with high quality, competitive price and timely delivery. We sincerely welcome friends from all over the world to cooperate with us and enlarge our business. If you are interested in our products, please feel free to contact us. We would love to provide you with further information.
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Betty from Muscat - 2017.10.25 15:53
    Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Pearl from Tunisia - 2017.12.31 14:53
    Write your message here and send it to us